Heading | 05/18/2022 | ROUGH FRAMING | Daniel Amador | DENIED | eTRAKiT Inspection Request | 5/17/2022 1:29:12 PM
5/17/2022 1:29 PM SANDSTONE CONSTRUCTION LLC
Requesting for an on site inspector consultation to review questions regarding framing/structure of the scope before framing begins.
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
5/18/2022 10:06:54 AM
Not ready for rough inspection. On site courtesy walk.
|
|
Heading | 10/05/2022 | UNDERGROUND PLUMB | Steven Ramirez | DENIED | Please see comments | 10/4/2022 4:27:58 PM
PM PLZ
10/5/2022 9:12:21 AM
Not ready for inspection. No inspection.
1. Must have test on the water lines and DWV system.
2. Must have approved city plans on site.
3. Must vent the bathroom group properly (shower and water closet)
4. Must submit gas isometric drawings to a plan examiner with the city and it must be approved by the city pan examiner prior to requesting a gas piping inspection.
5. You shall not run the gas piping under the building. It must rise above grade before entering the building.
6. This is not a complete list of everything that needs to be corrected so please have the contractor make sure the work is 100% complete prior to requesting any inspections.
|
|
Heading | 10/07/2022 | ROUGH PLUMBING | Steven Ramirez | APPROVED | eTRAKiT Inspection Request | 10/5/2022 7:00:41 PM
10/5/2022 7:00 PM PINEDO & ASSOCIATES INC
Contact Name: PINEDO & ASSOCIATES INC
Site Address: 5720 1/2 REED ST
Phone: 3037284656
e-Mail: [email protected]
|
|
Heading | 10/10/2022 | STRUCTURAL SHEATHING | Frank Goodard | CANCELLED | eTRAKiT Inspection Request | 10/9/2022 6:58:36 PM
10/9/2022 6:58 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
10/10/2022 9:03:20 AM
By office
|
|
Heading | 10/11/2022 | STRUCTURAL SHEATHING | Frank Goodard | CANCELLED | eTRAKiT Inspection Request | 10/10/2022 11:11:40 AM
10/10/2022 11:11 AM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
10/11/2022 8:22:54 AM
By office
|
|
Heading | 10/12/2022 | STRUCTURAL SHEATHING | Frank Goodard | DENIED | eTRAKiT Inspection Request | 10/11/2022 1:49:17 PM
10/11/2022 1:49 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
10/12/2022 2:06:35 PM
1. Need engineer to show shear wall locations on the approved plans.
2. Need strap location ID on approved plans.
3. Need anchor bolt / hold down locations.
10/12/2022 2:38:04 PM
NOTE: THERE ARE ISSUES WITH THE APPROVED PLANS WHERE THEY DO NOT SHOW THE SETBACKS TO THE PROPERTY LINE BECAUSE IT WAS AN EXISTING STRUCTURE PREVIOUSLY. REGARDLESS OF IT BEING AN EXISTING STRUCTURE, IT IS BEING MODIFIED SO THE FIRE SEPARATION DISTANCES AND REQUIREMENTS PER TABLE R302.1(1) WILL BE REQUIRED TO BE MET. REVISED PLANS WILL NEED TO BE SUBMITTED TO SHOW HOW THE ONE HOUR RATED WALL ASSEMBLY WILL BE ACHEIVED WITH RATING FROM BOTH SIDES. ALSO, DOCUMENTATION AND A CALCULATION WILL BE REQUIRED TO BE SUBMITTED TO SHOW THAT THE 25% WALL OPENINGS LIMITATIONS ARE BEING MET AND THE ONE HOUR RATING ON THE UNDERSIDE OF ANY PROJECTIONS WILL NEED TO BE MET AND DEMONSTRATED ON PLANS. PER SECTION R105.4 OF THE 2018 IRC, THE ISSUANCE OR GRANTING OF A PERMIT SHALL NOT BE CONSTRUED TO BE A PERMIT FOR OR AN APPROVAL OF ANY VIOLATION OF ANY OF THE PROVISIONS OF THE 2018 IRC. THE BUILDING OFFICIAL AND DESIGNEES ARE ALLOWED TO REQUEST THE CORRECTION OF ERRORS IN CONSTRUCTION DOCUMENTS.
|
|
Heading | 10/20/2022 | ROUGH HVAC | Steven Ramirez | PARTIAL INSPECTION | eTRAKiT Inspection Request | 10/19/2022 4:18:52 PM
10/19/2022 4:18 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
10/20/2022 7:57:32 AM
Dryer vent and exhaust fan in the bathroom only. Where is the heating unit? If you plan on installing a ductless split system, we have to see the condensation drain and refrigeration lines installed at the rough stage.
|
|
Heading | 10/20/2022 | ROUGH PLUMBING | Steven Ramirez | APPROVED | eTRAKiT Inspection Request | 10/19/2022 4:20:35 PM
10/19/2022 4:20 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
|
|
Heading | 10/21/2022 | ROUGH HVAC | Brad Umbarger | APPROVED | eTRAKiT Inspection Request | 10/20/2022 4:38:21 PM
10/20/2022 4:38 PM SANDSTONE CONSTRUCTION LLC
Please contact Hunter Smith at 720.413.4793 if the inspection will be before 9am. We want to ensure someone is on site.
Thanks.
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
10/21/2022 8:26:19 AM
Per Hunter, the heating will be floor heating cables throughout. An inspection for the heating cables, while on the manufacturer and required test, and with the documentation of the test readings from the manufacturer instructions shall be on site for the heating cables inspection.
|
|
Heading | 10/27/2022 | ELEC SERVICE/CL | Adam Quintana | APPROVED | | 10/27/2022 2:00:47 PM
Close loop.
|
|
Heading | 10/27/2022 | HOUSE WRAP | Frank Goodard | DENIED | eTRAKiT Inspection Request | 10/26/2022 8:45:16 AM
10/26/2022 8:45 AM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
10/27/2022 2:04:28 PM
1. S/S never passed inspection.
2. Remove all house wrap.
3. Provide information that was requested at S/S inspection on 10/12/22.
|
|
Heading | 10/27/2022 | ROUGH ELECTRIC | Adam Quintana | APPROVED | eTRAKiT Inspection Request | 10/26/2022 8:45:15 AM
10/26/2022 8:45 AM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
|
|
Heading | 01/13/2023 | HOUSE WRAP | Jason Fowler | PARTIAL INSPECTION | eTRAKiT Inspection Request | 1/12/2023 4:35:35 PM
1/12/2023 4:35 PM SANDSTONE CONSTRUCTION LLC
Project Manager:
Hunter Smith - 720.413.4793
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
1/13/2023 11:07:41 AM
Partial pass for house wrap. complete all flashing above windows.
recall back in when backorder windwos are installed. ok to proceed with siding.
|
|
Heading | 01/30/2023 | INSULATION | Jason Fowler | APPROVED | eTRAKiT Inspection Request | 1/29/2023 9:05:24 PM
1/29/2023 9:05 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
|
|
Heading | 04/25/2023 | ELEC SERVICE/CL | Brad Umbarger | APPROVED | eTRAKiT Inspection Request | 4/24/2023 9:54:55 PM
4/24/2023 9:54 PM SANDSTONE CONSTRUCTION LLC
Need a Meter Release
Contact Name: Hunter Smith
Site Address: 144 S EMERSON ST
Phone: 7204134793
e-Mail: [email protected]
|
|
Heading | 04/25/2023 | FINAL ELECTRICAL** | Brad Umbarger | FINAL | eTRAKiT Inspection Request | 4/24/2023 8:21:54 PM
4/24/2023 8:21 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
4/24/2023 8:32:09 PM
4/24/2023 8:32 PM SANDSTONE CONSTRUCTION LLC
Need final electrical inspection as well as a meter release.
Call Hunter at 720.413.4793
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
|
|
Heading | 04/25/2023 | FINAL HVAC** | Frank Goodard | APPROVED | eTRAKiT Inspection Request | 4/24/2023 8:23:29 PM
4/24/2023 8:23 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
|
|
Heading | 04/25/2023 | FINAL PLUMBING** | Frank Goodard | APPROVED | eTRAKiT Inspection Request | 4/24/2023 8:29:58 PM
4/24/2023 8:29 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
|
|
Heading | 04/25/2023 | ROOFING** | Frank Goodard | APPROVED | eTRAKiT Inspection Request | 4/24/2023 8:29:59 PM
4/24/2023 8:29 PM SANDSTONE CONSTRUCTION LLC
Contact Name: SANDSTONE CONSTRUCTION LLC
Site Address: 5720 1/2 REED ST
Phone: 3038873357
e-Mail: [email protected]
|
|
Heading | 05/11/2023 | FINAL STRUCTURAL** | Frank Goodard | FINAL | | |
|