Additional Information
Type of Work Completed : Water and Sewer Demolition
If street cut, size of cut : 4x4 water, 7x5 sewer
Traffic control contractor : Colorado Barricade
Date of Work End : Jun 8 2021 12:00AM
New Water Service Size : 3/4"
Location of work : Street and Yard
Street cut contractor : Mendoza Sewer & Water Services, Inc.
Date of Work Start : Jun 8 2021 12:00AM
Locate Confirm. No. : B115302360
Permit Information
PERMIT IS NOT VALID UNTIL FEES HAVE BEEN PAID
- Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 180 days after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced.
- This permit, approved plan sets, and other required documents for this project shall be printed and kept on site until the completion of the project.
- Call Before You dig, Call 811 3 working days before the project starts for locations of all utility lines.
- Backflow assembly tests must be sent to [email protected].
The issuance of this permit, any inspections made, or certificates of occupancy issue shall not be construed to be a permit for, nor an approval of any violation of Building Codes, Engineering Standards and Specifications, or any other code or ordinance adopted by the City of Arvada. Failure to comply with these laws or correct deficient work shall lead to an immediate revocation of the permit. Per sections 69.0 and 78-309 of the Arvada Municipal Code, the permittee shall be responsible for and bear the sole cost of any required relocation of their facilities located in or adjacent to public rights-of-way whether above or below ground. By accepting this permit, the permittee acknowledges this requirement.
Information you submit to the City of Arvada may be subject to the Colorado Open Public Records Act ("CORA"), C.R.S. ยง24-72-201 et seq. Information you submit via the City's application system will be viewable by the public. As such, do not upload any Personal Identifying Information such as driver's licenses, passports, social security numbers, credit card information, bank account information or dates of birth. The City of Arvada, its officers, employees or agents shall not be liable for damages or losses of any kind arising out of or in connection with the use or performance of information, including but not limited to, damages or losses caused by reliance upon the accuracy or timeliness of any such information, or damages incurred from the viewing, distributing, or copying of those materials.
Utility Locates
All utilities must be identified through the locate process prior to excavation of soil, including boring, can take place. In the event, that a City Utility cannot be located within the specified boundaries of the request area, the contractor/excavator will be notified by e-mail and/or phone of a mandatory on-site meeting to discuss alternate measures for protecting the utility. No excavation of soil, including boring, is permitted until the on-site meet has taken place and all utilities have been located. Failure to comply will be deemed unreasonable action by the contractor/excavator and may result in the contractor/excavator assuming all liability for damages to such utilities
Color |
|
Description |
|
Red |
Electric power lines, cables, conduit, and lighting cables |
|
Orange |
Telecommunication, alarm or signal lines, cables, or conduit |
|
Yellow |
Natural gas, oil, steam, petroleum, or other gaseous, or flammable material |
|
Green |
Sewers and drain lines |
|
Blue |
Drinking water |
|
Purple |
Reclaimed water, irrigation, and slurry lines |
|
Pink |
Temporary survey markings, unknown/unidentified facilities |
|
White |
Proposed excavation limits or route |