| Heading | 08/06/2024 | RADON | Daniel Amador | PARTIAL INSPECTION | eTRAKiT Inspection Request | 8/5/2024 1:09:48 PM
8/5/2024 1:09 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
8/6/2024 9:56:49 AM
First phase only.
|
|
| Heading | 08/30/2024 | STRUCTURAL SHEATHING | Pete Henz | APPROVED | eTRAKiT Inspection Request | 8/29/2024 11:34:48 AM
8/29/2024 11:34 AM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 09/10/2024 | FIRE RATED WALL | Daniel Amador | CANCELLED | eTRAKiT Inspection Request | 9/9/2024 3:26:39 PM
9/9/2024 3:26 PM TAYLOR MORRISON
Fire soffit
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3039067185
e-Mail: [email protected]
9/10/2024 10:34:27 AM
Duplicate request.
|
|
| Heading | 09/10/2024 | FIRE RATED WALL | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 9/9/2024 3:26:41 PM
9/9/2024 3:26 PM TAYLOR MORRISON
Fire soffit
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3039067185
e-Mail: [email protected]
9/10/2024 10:35:52 AM
5/8" drywall on both elevation soffits ok.
|
|
| Heading | 09/10/2024 | HOUSE WRAP | Daniel Amador | CANCELLED | eTRAKiT Inspection Request | 9/9/2024 3:26:38 PM
9/9/2024 3:26 PM TAYLOR MORRISON
Fire soffit
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3039067185
e-Mail: [email protected]
9/10/2024 10:34:12 AM
Duplicate request.
|
|
| Heading | 09/10/2024 | HOUSE WRAP | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 9/9/2024 3:26:41 PM
9/9/2024 3:26 PM TAYLOR MORRISON
Fire soffit
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3039067185
e-Mail: [email protected]
|
|
| Heading | 09/16/2024 | CONSTRUCTION METER | Mike McDonald | APPROVED | eTRAKiT Inspection Request | 9/13/2024 1:50:35 PM
9/13/2024 1:50 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 10/03/2024 | GAS METER RELEASE | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 10/2/2024 3:17:56 PM
10/2/2024 3:17 PM C&T PLUMBING LLC
Contact Name: C&T PLUMBING LLC
Site Address: 16508 W 92ND PL
Phone: 3039781051
e-Mail: [email protected]
|
|
| Heading | 10/03/2024 | GAS PIPING | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 10/2/2024 3:16:35 PM
10/2/2024 3:16 PM C&T PLUMBING LLC
Contact Name: C&T PLUMBING LLC
Site Address: 16508 W 92ND PL
Phone: 3039781051
e-Mail: [email protected]
|
|
| Heading | 10/03/2024 | ROUGH PLUMBING | Daniel Amador | DENIED | eTRAKiT Inspection Request | 10/2/2024 3:15:14 PM
10/2/2024 3:15 PM C&T PLUMBING LLC
Contact Name: C&T PLUMBING LLC
Site Address: 16508 W 92ND PL
Phone: 3039781051
e-Mail: [email protected]
10/3/2024 10:45:05 AM
Horizontal branches shall connect to the bases of stacks at a point located not less than 10 times the diameter of the drainage stack downstream from the stack. (master bathroom group stack and kitchen drain)
|
|
| Heading | 10/04/2024 | ROUGH ELECTRIC | Mike McDonald | APPROVED | eTRAKiT Inspection Request | 10/3/2024 1:47:09 PM
10/3/2024 1:47 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 10/04/2024 | ROUGH HVAC | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 10/3/2024 1:47:09 PM
10/3/2024 1:47 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 10/07/2024 | ROUGH PLUMBING | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 10/4/2024 9:42:55 AM
10/4/2024 9:42 AM C&T PLUMBING LLC
Contact Name: C&T PLUMBING LLC
Site Address: 16508 W 92ND PL
Phone: 3039781051
e-Mail: [email protected]
|
|
| Heading | 10/08/2024 | ROUGH FRAMING | Daniel Amador | DENIED | eTRAKiT Inspection Request | 10/7/2024 3:10:07 PM
10/7/2024 3:10 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
10/8/2024 10:04:40 AM
1) Fireblock dead space ceiling at chase in garage
2) bottom plate missing anchors in garage, check all
3) missing full depth blocking above shear wall in dinning room
4) attach (3) LSL's to post with (3) CS16 in dinning room per engineer specs
5) no ladder setup in master and it appears trusses missing clips or wedging at over frame
6) trusses A02's bracing in the wrong location
|
|
| Heading | 10/11/2024 | ROUGH FRAMING | Pete Henz | APPROVED | eTRAKiT Inspection Request | 10/10/2024 12:19:43 PM
10/10/2024 12:19 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 10/16/2024 | INSULATION | Mike McDonald | APPROVED | eTRAKiT Inspection Request | 10/15/2024 8:35:13 AM
10/15/2024 8:35 AM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 10/16/2024 | RADON | Mike McDonald | APPROVED | eTRAKiT Inspection Request | 10/15/2024 8:35:13 AM
10/15/2024 8:35 AM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 10/29/2024 | DRYWALL | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 10/28/2024 8:58:49 AM
10/28/2024 8:58 AM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 11/18/2024 | ELEC SERVICE/CL | Mike McDonald | APPROVED | eTRAKiT Inspection Request | 11/15/2024 12:59:58 PM
11/15/2024 12:59 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 12/05/2024 | CO-PUBLIC IMPROVMNT | Robert Gonzales | DENIED | CO public improvement | 12/4/2024 11:39:36 AM
12/4/2024 11:39 AM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
12/5/2024 11:36:15 AM
Denied - Sidewalk dirty/damaged sidewalk concrete stones
|
|
| Heading | 12/11/2024 | FINAL ELECTRICAL** | Greg Thomas | DENIED | eTRAKiT Inspection Request | 12/10/2024 4:04:13 PM
12/10/2024 4:04 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
12/11/2024 12:43:02 PM
1. instant trip @ AC 120 recept
2. Clearance for Water Heater disconnect not met [110.26]
3. Furnace missing [interior] Jbox cover
4. in crawl space- switch for fan hanging out of box missing cover plate
5. missing cover plate in master bath closet [dueplex]
no ladder set for attic inspection
|
|
| Heading | 12/11/2024 | FINAL HVAC** | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 12/10/2024 4:04:13 PM
12/10/2024 4:04 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 12/11/2024 | FINAL PLUMBING** | Daniel Amador | DENIED | eTRAKiT Inspection Request | 12/10/2024 4:06:13 PM
12/10/2024 4:06 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
12/11/2024 12:35:28 PM
1) paint gas line
2) seal irrigation pipe penetration and check all penetrations
3) sump pump not operational and paint discharge pipe
|
|
| Heading | 12/13/2024 | FINAL ELECTRICAL** | Mike McDonald | APPROVED | eTRAKiT Inspection Request | 12/12/2024 1:20:48 PM
12/12/2024 1:20 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 12/16/2024 | CO-PUBLIC IMPROVMNT | Robert Gonzales | APPROVED | CO public improvement | 12/13/2024 12:18:43 PM
12/13/2024 12:18 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
12/16/2024 11:29:16 AM
CO Public Improvement - Approved. Some of the new sidewalk stone will work need to R&R'd due to damage after it was poured before initial warranty.
|
|
| Heading | 12/16/2024 | FINAL PLUMBING** | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 12/13/2024 11:55:21 AM
12/13/2024 11:55 AM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 12/17/2024 | FINAL STRUCTURAL** | Daniel Amador | APPROVED | eTRAKiT Inspection Request | 12/16/2024 11:55:33 AM
12/16/2024 11:55 AM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|
| Heading | 12/18/2024 | CO/TCO | Monique Ramirez | ACCEPTED | eTRAKiT Inspection Request | 12/17/2024 2:19:01 PM
12/17/2024 2:19 PM TAYLOR MORRISON
Contact Name: TAYLOR MORRISON
Site Address: 16508 W 92ND PL
Phone: 3032101812
e-Mail: [email protected]
|
|